- Power Quality Improvement for Thirty Bus System Using UPFC and TCSC
Abstract Views :252 |
PDF Views:0
Authors
Affiliations
1 Sathyabama University, Chennai, IN
2 Sathyabama University, Chennai
1 Sathyabama University, Chennai, IN
2 Sathyabama University, Chennai
Source
Indian Journal of Science and Technology, Vol 7, No 9 (2014), Pagination: 1316-1320Abstract
This work deals with power quality improvement by using FACTS devices. When the reactive power of the load is changing continuously, a suitable fast response compensator is needed. Unified Power Flow Controller and Thyristor Controller Series Capacitor are two such compensators belonging to FACTS devices which are used in this work. Models for the UPFC and TCSC are developed using MATLAB Simulink. The simulation results for thirty bus system with UPFC and TCSC are presented.Keywords
FACTS Controller, MATLAB, Simulink, TCSC, UPFC- Honey Bees Searching Optimization for Non Convex Dynamic Power Dispatch Problem in Thermal Units
Abstract Views :211 |
PDF Views:0
Authors
Affiliations
1 Department of Electrical and Electronics Engineering,Sathyabama University, Chennai - 600119, Tamil Nadu, IN
2 School of Electrical Engineering, Vellore Institute of Technology (VIT) University, Chennai - 632014, Tamil Nadu, IN
1 Department of Electrical and Electronics Engineering,Sathyabama University, Chennai - 600119, Tamil Nadu, IN
2 School of Electrical Engineering, Vellore Institute of Technology (VIT) University, Chennai - 632014, Tamil Nadu, IN
Source
Indian Journal of Science and Technology, Vol 8, No 18 (2015), Pagination:Abstract
Dynamic Power Dispatch (DPD) intends to schedule the online generators output with the forecasted load demand over a certain period of time, in order to operate an electric power system most economically within its operating limits. The behavior and the activity of honey bees during food foraging is implemented as a Honey Bees Searching Optimization (HBSO) technique in solving the DPD problem. The HBSO algorithm provides a balance between exploration and exploitation of a search space. Further, the HBSO is independent of control parameters when compared to other techniques. The DPD formulation includes ramp rate constraint, rectified sinusoidal effect, uniformity and disparity constraint, which normally present in the realistic power system. In order to express the efficacy of the HBSO algorithm a test case of 6 units DPD problem is considered and lower fuel cost is obtained when compared with other algorithm.Keywords